    Product Details:

    Place of Origin: China
    Brand Name: MITECH
    Certification: CE
    Model Number: MDC Series

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 piece
    Price: USD
    Packaging Details: standard export carton
    Payment Terms: T/T, Western Union Paypal
    Supply Ability: 500 per day
    Contact Now
    Detailed Product Description
    Digital Timer: 1~999min,resolution 1min Cooling Medium: Ethanol Or Other Antifreeze
    Power Supply: 220V~240V,50HZ
    High Light:

    tensile testing machine

    ,

    mechanical testing equipment

     

    Mitech Mechanical Testing Machine MDC Series Impact Test Low Temperature Meter

    Overview

     

    Mitech MDC Series Impact test low temperature meter,adopt imported compressor refrigeration technology, heat balance principle and the way of mixing, can achieve the sample of automatic uniform cooling, constant temperature storage, its strong structure, simple structure, easy operation, high efficiency, low temperature impact test material is the best test Like cooling, insulation equipment, but also for other low temperature testing and testing work.

    Mitech Mechanical Testing Machine MDC Series Impact Test Low Temperature Meter 0

    Technical Parameters

     

    Technical Parameters

     

    MDC-60 MDC-80

    MDC-80

    (Liquid nitrogen)

    MDC-100

    MDC-100

    (Liquid nitrogen)

    Temperature range +30℃~- 60℃ +30℃~- 80℃ +30℃~- 80℃ +30℃~- 100℃ +30℃~- 100℃
    Constant temperature accuracy ±0.5℃ ± 3℃
    Cooling rate

    +30℃~0℃ about 1.5℃/min

    0℃~-20℃ about 1.3℃/min

    -20℃~-40℃ about 1.0℃/min

    -40℃~—60℃ about 0.7℃/min

     

    +30℃~-40℃ about1.8℃/min 40℃~-80℃ about1.5℃/min -80℃~100℃ about0.7℃/min about8℃/min
    Effective working space 120*120*70mm 120*120*70mm 220*170*120mm 150*150*240mm 220*170*120mm
    The number of samples can be loaded >60(Impact specimen size:10*10*55mm) >100(Impact specimen size:10*10*55mm)
    Digital timer 1~999min,resolution 1min
    Cooling medium Ethanol or other antifreeze
    Dimensions mm 900*505*850 900*505*850 700*600*800 1500*1200*1200 700*600*800
    Size of liquid nitrogen tank mm     650*650*1000   650*650*1000
    Power supply 220V~240V,50HZ

     

    Working Principle

    Impact test low temperature meter,adopt imported compressor refrigeration technology, heat balance principle and the way of mixing, can achieve the sample of automatic uniform cooling, constant temperature storage

    Features

    • Widely used in materials, low temperature impact test sample cooling, constant temperature storage, can also be used for other low temperature testing and testing work;
    • The use of imported compressor refrigeration technology, heat balance principle and the cycle of mixing, high efficiency;
    • Strong structure, simple structure, stable performance, easy operation, can also cool a number of test pieces;
    • Consistent with GB, ISO, ASTM and other relevant domestic and foreign standards.

     

    Scope of application

     

    Widely used in low temperature impact test samples of the sample cooling, constant temperature storage.

    Applications

    • Quality control link of Metal processing manufacturing
    • Quality control link of nonmetal manufacturing industry
    • Teaching experiment of scientific research in Institutions of higher learning
    • Material analysis test of scientific research institutions
    • Quality inspection link of Quality inspection department

     

    Working Conditions

     

    • Relative humidity:20%~80%;
    • No corrosive medium, no high magnetic field interference;
    • Horizontal installation on a solid basis;
    • Power supply voltage fluctuation does not exceed 10% of rated voltage.

     

    Configurations

     

    Configuration instructions NO. Name QTY. Remarks
    Standard Configuration 1 Low temperature meter host 1  
    2 Sample placing rack 1  
    3 Sample basket 3  
    4 Attached files 1  

     

    Maintenance and care

     

     

    Read the manual carefully before using the instrument. Learn the operation steps and attentions to avoid damage the instrument or personal safety accidents caused by improper operation;

    l Test machine is a large precision instruments, should pay attention to water, moisture. Exposed workstations, upper and lower beam parts and attached parts should be coated with anti-rust oil to prevent rust;

    l The instrument power supply should be reliably grounded and equipped with regulator device;

    l To ensure the accuracy of cryogenic instruments,the instrument needs to be checked at least once a year;

    l Don’t disassemble the instrument without authorization, maintenance related matters please contact MITECH after-sale service department with 4000600280.

     